Great Win Fire & Safety LLC provides clean-agent fire suppression solutions as part of its fire protection and life safety services across Dubai and Abu Dhabi. Our capabilities include FM-200 equipment, suppression cylinder refilling, testing, and related maintenance support to help clients manage their fire protection requirements.

Great Win Fire & Safety LLC provides design, installation, testing, commissioning and maintenance of clean agent fire suppression systems in Dubai and Abu Dhabi. We support FM-200, Novec 1230 and IG-541 installations for server rooms, data centres, telecommunications facilities, electrical switchgear rooms and control rooms. Clean agents suppress fire without leaving extinguishing residue on sensitive equipment.

For a total-flooding system, the room itself forms part of the protection. The system must deliver the correct quantity of agent throughout the protected space, and the enclosure must retain it for the required period. A new cable opening, an unsealed raised floor or a change to the ventilation system can affect that performance.

Clean agent fire suppression system

FM-200, Novec 1230 and IG-541 Systems

System How it works What we assess
FM-200 (HFC227ea) The agent is stored as a gas and discharged through fixed pipework and nozzles. It suppresses fire primarily by absorbing heat. Cylinder capacity, installed agent quantity, nozzle coverage and whether changes to the room affect the original design.
Novec 1230 (FK5-1-12) Novec 1230 is 3M’s trade name for an FK-5-1-12 extinguishing fluid. The agent vaporises on discharge and absorbs heat. For existing systems, we check the manufacturer, model and approved refill specification. For new FK-5-112 proposals, we identify the proposed agent and system manufacturer by name.
IG-541 inert gas IG-541 uses a blend of nitrogen, argon and carbon dioxide to reduce the oxygen concentration in the protected space and suppress combustion. A system can protect one room or serve several zones from a common cylinder bank. Cylinder bank space, delivery access, pipe routes, zone selection and enclosure pressure relief.

For facilities with an existing Novec 1230 system, identifying the original equipment is particularly important. 3M completed its exit from PFAS manufacturing at the end of 2025. When preparing a refill proposal, we check agent availability and compatibility with the installed system before quoting a product or lead time.

System Design and Installation

Protected room survey.

We review the fire hazard, room dimensions, occupancy, equipment layout and available cylinder space. Raised floors and ceiling voids receive specific attention so the drawings clearly show which spaces the system protects.

Agent calculations and equipment layout.

We determine the agent quantity and use the selected manufacturer’s design method to calculate pipe sizes and nozzle arrangements. Installation drawings identify cylinder locations, pipe routes, discharge nozzles, detection devices, warning signs and control equipment. We also review access for future cylinder removal and refilling.

Detection, alarms and building interfaces.

We coordinate the releasing control panel with the fire detection system, pre-discharge sounders and visual warnings, manual release stations and abort controls where specified. The approved operating sequence defines when occupants receive a warning, which ventilation equipment or dampers respond, and which signals reach the main fire alarm panel.

Room integrity testing and commissioning

Room Integrity Testing and Commissioning

A door fan test helps assess whether an enclosure can retain the extinguishing concentration for the required period. Where included in the project scope, we arrange the test, document leakage concerns and coordinate corrective work and retesting. Typical inspection points include cable penetrations, door seals, ducts and openings beneath raised floors. We assess discharge pressure relief separately because it serves a different purpose from agent retention.

During commissioning, we verify the detection and release sequence through controlled functional tests. This includes panel indications, warning devices, manual controls and agreed interfaces with ventilation and fire alarm systems.

Handover can include as-built drawings, agent and flow calculations, cylinder records, room integrity results, commissioning reports and a demonstration for the facility team.

Maintenance, Cylinder Refilling and Reinstatement

Our maintenance scope covers cylinders, valves, actuators, hoses, pipework, nozzles, releasing panels and warning devices. We check agent quantity or cylinder pressure using the method applicable to the system and record any room alterations that may require an engineering review.

Following a discharge or a cylinder service requirement, we coordinate refilling, hydrostatic testing where due, reinstallation and reinstatement checks. Before a cylinder leaves site, we identify the affected room or zone and agree on the impairment period and temporary precautions with facility management.

On completion, we document the return to service so the operator knows when automatic protection has been restored.

Clean agent cylinder maintenance and refilling

Description

Clean-agent fire suppression systems are used in applications where specialised fire protection is required. Great Win Fire & Safety LLC supports clean-agent suppression requirements through equipment supply and installation, according to the project scope and applicable fire safety requirements.

Our company profile lists FM-200 equipment among our fire protection capabilities and identifies support for refilling suppression cylinders containing agents such as FM-200 (HFC-227ea), NOVEC 1230, NAF S 125, IG-55, and IG-541.

We also provide cylinder hydrotesting, leakage testing, and related certification support through our in-house refilling facility. These services help clients address the inspection, testing, and refilling needs of their fire suppression equipment.

Book an Appointment

Need support with clean-agent fire suppression equipment, cylinder refilling, or system maintenance? Contact Great Win Fire & Safety LLC to discuss your requirements and the scope of service needed.

Contact Form
Emergency Call 24/7

+971 54 420 5727

Our Capability

Clean-Agent Fire Protection Support

Our listed capabilities cover FM-200 equipment, suppression cylinder refilling, testing, and related fire protection services. The specific scope is determined by the project requirements and the equipment involved.

Our capabilities cover key stages of fire protection project delivery, from system design and equipment selection to installation, testing, commissioning, and ongoing maintenance.

FM-200 Fire Suppression
0%
Suppression Agent Refilling
0%
Hydrotesting & Leakage Testing
0%
Inspection & Certification Support
0%

Why Choose Us

Specialised Fire Protection & Cylinder Support

Established in 2018, Great Win Fire & Safety LLC provides fire protection and life safety services across Dubai and Abu Dhabi, including clean-agent equipment and suppression cylinder support.

In-House Refilling Facility

Our company profile identifies an in-house facility for fire suppression cylinder refilling and fire extinguisher recharge services.

Testing & Documentation

Our services include cylinder hydrotesting, leakage testing, and relevant certificates for the work performed.

Ongoing Service Support

We provide maintenance support and 24/7 AMC services across Dubai and Abu Dhabi.

Contact Great Win Fire & Safety LLC

Discuss your clean-agent fire suppression requirements with our team. Whether you need FM-200 equipment support, suppression cylinder refilling, hydrotesting, leakage testing, or maintenance assistance, we can review your requirements and advise on the applicable service scope.