Skip to main content

Great Win Fire & Safety L.L.C.

Emergency and exit light system

Emergency and exit lighting systems provide clear visibility and guide occupants safely towards designated exits during power failures or emergencies. 

When normal lighting fails, occupants need to see both the path ahead and the direction to the nearest designated exit. Emergency lights illuminate the escape route, including corridors, stairs and changes in level. Illuminated exit signs guide people at decision points, such as corridor junctions and the approach to an exit door.

Great Win Fire & Safety LLC provides design, supply, installation, testing, commissioning and maintenance of emergency and exit lighting systems in Dubai and Abu Dhabi. We work with building owners, consultants, contractors and facility managers on new developments, tenant fit-outs and upgrades to occupied buildings.

Emergency lighting and exit signage

Emergency Lighting and Exit Signage Application

Escape routes and staircases

Emergency lighting for corridors, stair flights, landings, ramps and final exit routes. We review changes of direction and level so the layout accounts for the full journey out of the building.

Exit and directional signs

Illuminated signs at exits and along escape routes. We select the arrow direction, sign size, mounting position and single- or double-sided format according to where occupants will approach and how far away they need to see the sign.

Open areas

Emergency lighting for spaces such as open-plan offices, retail floors and assembly areas, helping occupants find their way to a defined escape route when normal lighting fails.

Warehouses and industrial premises

Fittings selected for the mounting height and site conditions.We check lighting coverage and sign visibility against rack positions, aisle layouts, mezzanines and loading areas.

External routes and final exits

Weather-resistant fittings where the designated escape route continues beyond the exit door. We review external steps, ramps and changes in direction within the project scope.

Self-contained and central battery emergency lighting systems

Self-Contained and Central Battery Systems

Self-contained emergency lights and exit signs have a battery within each fitting. They can suit individual premises, tenant fit-outs and phased refurbishments. Depending on the equipment selected, fittings can support local testing, automatic self-testing or central monitoring that identifies individual faults.

Central battery systems supply emergency power to compatible lights and exit signs from a common battery installation. For a new system, we review the connected load, required operating duration, circuit arrangement and monitoring provisions. When extending an existing system, we check spare capacity and fitting compatibility before specifying additional units.

The operating mode is selected separately from the battery arrangement. A maintained fitting can illuminate during normal operation and continue on emergency power. A non-maintained fitting lights when its monitored normal supply fails. We select the mode for each location against the approved design.

Design, Installation and Commissioning

Survey and layout review.

We follow the designated escape routes on the drawings and on site. We check door positions, staircases, ceiling heights and sightlines, including whether an occupant approaching a junction can see the correct directional sign before choosing where to turn.

Lighting design and equipment selection.

We prepare layouts, fitting schedules and lighting calculations within the agreed scope. We use the selected fitting’s light distribution and mounting height to assess coverage against the project criteria. The drawings identify fitting types, sign directions, power sources and circuit references.

Installation and coordination.

We coordinate mounting positions with ceilings, partitions, services and architectural signage. In warehouses and retail premises, we also check whether racks, bulkheads or shop signs will obscure an exit sign after fit-out.

Functional and duration testing.

A functional test checks that the designated fittings illuminate when the monitored normal supply fails. A duration test checks whether they continue operating for the period specified for the project. We record failed fittings and battery faults by location so the maintenance team can find and rectify them. For occupied buildings, we agree on test timing and battery recharge arrangements with site management.

Inspection support and handover.

We support consultant, landlord and Civil Defence inspections within the agreed scope. Handover documents can include as-built layouts, a fitting register, circuit schedules, test results, equipment manuals and outstanding corrective actions.

Maintenance, Fit-Outs and Upgrades

A fitting can pass a brief switch-on check yet fail to remain lit for its required duration. An exit sign can also be fully operational while pointing towards a route that changed during refurbishment. Our maintenance visits address both equipment condition and the route occupants actually use.

Under an Annual Maintenance Contract, we can inspect fittings and signs, review battery and charger condition, investigate central system faults, carry out scheduled tests and record corrective work. For fit-outs, we review affected routes, relocate or add fittings, correct directional arrows and update the lighting layout and test records.

Description

Great Win Fire & Safety LLC provides fire protection solutions designed around project requirements and applicable fire safety regulations. Our capabilities include the supply and installation of fire water sprinkler systems, hose reels, and FM-200 equipment, along with related fire fighting system services.

From new installations to existing system maintenance and rectification, we support projects through coordinated delivery, testing, commissioning, and Annual Maintenance Contracts (AMC).

Our company profile identifies Great Win as DCD and ADCD approved, ISO 9001:2015 certified, and committed to NFPA-aligned practices.

Book an Appointment

Planning a new fire protection installation or need support with an existing system? Contact Great Win Fire & Safety LLC to discuss your project scope, equipment requirements, maintenance, or rectification needs.

Contact Form
Emergency Call 24/7

+971 54 420 5727

Our Capability

Integrated Fire Protection Services

Our capabilities cover key stages of fire protection project delivery, from system design and equipment selection to installation, testing, commissioning, and ongoing maintenance.

Fire Fighting System Installation
0%
Fire Alarm Integration
0%
Fit-Out & Rectification
0%
Refilling & Testing
0%

Why Choose Us

Safety, Compliance & Reliable Support

Established in 2018, Great Win Fire & Safety LLC provides fire protection and life safety services with a focus on quality, compliance, and ongoing support.

DCD & ADCD Approvals

Our company profile lists Dubai Civil Defense and Abu Dhabi Civil Defense approvals for relevant fire protection work.

ISO 9001:2015 Certified

Our quality management certification supports our commitment to structured processes and consistent service delivery.

24/7 AMC Support

Our maintenance support teams serve Dubai and Abu Dhabi, helping clients maintain their fire protection systems.

Ensure Safety with Reliable Emergency & Exit Lighting!

Keep your building safe and evacuation routes clearly illuminated during emergencies. Trust our experts for professional emergency lighting installation, testing and maintenance.